* Issue #157: the Windows portable zip keeps settings, logs and recovery beside pdfcraft.exe
The portable zip had no portable.txt, and the app had no portable mode: it always wrote %APPDATA%\PdfCraft and %LOCALAPPDATA%\PdfCraft. Now portable.txt (or PdfCraft.portable) beside the executable puts the settings, log files, crash recovery and new digital IDs in PdfCraftData next to it, as PhotoCraft does, and the zip ships portable.txt. An unwritable PdfCraftData falls back to the per-user folders and says so.
* Issue #157: update ATTRIBUTION.toml SHA-256 for the translation catalogs this PR changes
---------
Co-authored-by: Brandon Thomas <echelon@gmail.com>
* #305: harden Windows MSI deployment and progress UI
Co-authored-by: Codex <noreply@openai.com>
* Keep the MSI manufacturer as Learning Machines LLC
The company name matches the Linux packages; changing it is the owner's call.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* #305: keep compiled-MSI checks compatible with PowerShell COM
Validated the compiled x64 MSI and negative scope, publisher and progress mutations.
Co-authored-by: Codex <noreply@openai.com>
* ROADMAP: the publisher name is unchanged
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
---------
Co-authored-by: Codex <noreply@openai.com>
Co-authored-by: Brandon Thomas <echelon@gmail.com>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
* #143: Windows MSI desktop shortcut checkbox and install-complete dialog
Add native installer dialogs (installer-ui.wxs): a welcome screen with a
"Create a desktop shortcut" checkbox (ticked by default), repair/remove,
progress, and "Setup completed successfully" / failed / cancelled screens
with Finish. Unattended /qn and /qb installs never wait on a dialog and can
skip the desktop shortcut with INSTALLDESKTOPSHORTCUT=0.
Start Menu and desktop shortcuts are now plain links to pdfcraft.exe in
their own components (HKLM key paths, removed on uninstall) instead of
advertised MSI shortcuts.
test-msi.ps1 checks the compiled MSI's shortcut, checkbox and dialog tables
during packaging; the ARM64 install smoke test checks both shortcut
targets, their removal on uninstall, and the INSTALLDESKTOPSHORTCUT=0
opt-out.
Co-authored-by: ChatGPT <noreply@openai.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JqiBTPWGWbhQDYNFcxFte6
* #143: run test-msi out of process before signing; add files-in-use dialog
test-msi.ps1 held the MSI open through a Windows Installer COM handle in
package.ps1's own process, so signtool could fail on signed release builds.
Run it in a child process and release the COM objects.
The hand-authored UI had no MsiRMFilesInUse dialog, so an upgrade or repair
while PdfCraft is running could not offer to close it. Add one (OK closes the
programs with MSIRMSHUTDOWN=2, Cancel stops setup) and check for it in
test-msi.ps1.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01JqiBTPWGWbhQDYNFcxFte6
---------
Co-authored-by: ChatGPT <noreply@openai.com>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
Co-authored-by: Brandon Thomas <echelon@gmail.com>
The app, crates, binaries, bundle id, packaging, icons, screenshots and docs are now
PdfCraft / pdfcraft (repo storytold/pdfcraft). On first launch the desktop app moves the
PrintCraft settings and crash-recovery folders to the new name, and both apps read settings
saved under the old storage key, so upgrades keep recent files, preferences and unsaved work.
The signing test fixtures keep their PrintCraft subject names (they are binary).
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
The MSI registered no file association. The only PrintCraft entry a
user could pick in "Choose an app on your PC" was the advertised Start
Menu shortcut, which Windows can't run as a file handler ("This app
can't run on your PC").
The MSI now uses Windows' Default Programs registration: a
PrintCraft.Document ProgID (open command, icon), .pdf OpenWithProgids,
Applications\printcraft.exe (friendly name, supported types), and
Capabilities\FileAssociations listed under RegisteredApplications.
PrintCraft appears under "Open with" and in Settings > Default apps.
It never takes over an existing default: .pdf's own default value is
left alone, and the user chooses.
Checked locally with WiX 5.0.2: the MSI builds, passes ICE validation
(only the existing ICE61 note on same-version upgrades), and its
Registry table holds exactly these values.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The Linux package description, AppStream metadata (categories,
keywords, a screenshot that doesn't exist), the MSI's comment and the
web embedding example still described PhotoCraft. They now describe a
PDF workbench, AppStream lists application/pdf, and the screenshot is
one of ours.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Shippori Mincho (and its OFL file) leaves assets/fonts/: the Japanese fonts now
live in storytold/craft-fonts. printcraft-fonts gets craft-fonts' build.rs recipe:
with CRAFT_FONTS_DIR=<checkout> it embeds the manifest's fonts as CRAFT_FONTS
(wasm32: only BIZ UDPGothic Regular); without it CRAFT_FONTS is empty and the
app builds, tests and runs as before, minus the Japanese face.
- SHIPPORI_MINCHO is now Option<&[u8]> from CRAFT_FONTS; japanese_glyph
(was shippori_glyph) uses document_japanese_font() (Shippori Mincho, then
BIZ UDMincho, then any Jpan face) and returns GlyphError::NoFont without one.
- Editing PDF text into Japanese without craft-fonts is a clear EditError that
leaves the page untouched.
- UI: every Jpan craft font (BIZ UDPGothic first) is the last fallback of
every egui family, sharing the same static bytes.
- Tests: Japanese glyph/edit tests skip without craft-fonts; new UI tests for
no-tofu Japanese with craft-fonts and working fonts without it.
- CI: the Linux test job checks out craft-fonts at a pinned SHA and runs the
tests with CRAFT_FONTS_DIR. Releases build every platform with it
(CRAFT_FONTS_REQUIRED=1) and ship each font's OFL as OFL-<family>.txt.
- ATTRIBUTION.toml gains [[build_input]] (checked by xtask assets); NOTICE,
AGENTS.md, CLAUDE.md, README and docs say fonts live in craft-fonts.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The cross-compiled ARM64 binary can't run on the x64 packaging runner; the
windows-arm64 workflow installs and runs it on ARM64 instead. (x86 builds
still run there: x64 Windows runs them.)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- package.ps1 takes -Arch arm64 (aarch64-pc-windows-msvc, WiX -arch arm64)
and now checks each binary's PE Machine as well as its Subsystem, so an x64
build can never ship labelled arm64.
- release.yml builds, signs and packages a Windows ARM64 MSI and portable zip
next to x64 and x86, cross-compiled on the x64 runner so signing and WiX
run exactly as they do for x64.
- New windows-arm64.yml (PRs touching Cargo/packaging, main, weekly):
packages the ARM64 MSI the same way (unsigned), installs it on a Windows 11
ARM64 runner, checks both installed binaries are ARM64, opens/reads/edits/
renders/saves a PDF with the installed CLI, uninstalls; and runs the whole
test suite natively on ARM64. The MSI is kept as an artifact for 7 days.
- README: Windows builds for x64, x86 and ARM64.
Requested by @maxffarrell.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- printcraft.exe release builds use the GUI subsystem, so launching it no
longer opens a console window next to it (debug builds keep the console).
- The MSI's Icon id gains its .ico extension: Windows Installer requires it
for advertised shortcuts and ARPPRODUCTICON, so the Start Menu shortcut and
Add/Remove Programs showed a blank icon.
- Guards: package.ps1 checks the PE subsystem of both binaries (app = GUI,
CLI = console) before packaging; packaging-lint fails on an Icon id without
.ico/.exe.
- The shortcut's description said "image editor"; it's a PDF workbench.
Reported, with the exact fixes, by @MikailuReeves.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>