Guest faults are delivered on the guest stack, and the managed handler ran there. The runtime only knows the thread's own stack; Windows swaps the TEB stack bounds while guest code runs, but POSIX has no equivalent. A garbage collection during a guest fault then misread the thread's frames and reported garbage object references, and the process failed with "attempted to call a UnmanagedCallersOnly method from managed code". A small native trampoline now moves to the host stack below the frames that entered guest code before it calls the managed handler. |
||
|---|---|---|
| .. | ||